Set up

Before you start, make sure you have:

Power

To supply the ProtoPixel Gate Wired, connect the power supply (accepts 5-24 V DC) to the respective terminals of the pluggable screw connectors. Be mindful of where you connect the power supply cables; incorrect placement will permanently damage the ProtoPixel Gate Wired. You have indications of - + and data ports on the top of the controller. You’ll see the light turn on when you successfully connect it. Repeat with as many ProtoPixel Gate Wired as you wish to orchestrate (up to 10).

Connect to Power Supply. The Data Cable is already wired to WAGO connector.

Connect to Power Supply. The Data Cable is already wired to WAGO connector.

Always be careful with the order of the cables.

Always be careful with the order of the cables.

Factory Reset

Press & hold the push-button for 10s to restore the ProtoPixel Gate Wired to its factory settings. From the Configuration Tool on the WebApp: go to settings > general > factory reset.

Wiring

Wiring diagram for Standalone Installation:

Standalone Wiring DUO.png

Wiring Diagram for Orchestration:

Orchestration Wiring DUO.png